Canada Department of Energy, Mines and Resources, 1958
Two tracer tests were carried out during pilot plant smelter operations on a siliceous iron ore to measure the approximate residence time of sinter in the...
Canada Department of Energy, Mines and Resources, 1961
Air samples were taken during the melting and pouring of six 500 lb heats of uranium bearing steel containing varying amounts of uranium. The concentrations of...
Canada Department of Energy, Mines and Resources, 1961
Eleven uranium ore samples submitted by Western Nuclear Inc. have been assayed radiometrically. The samples contained 3-4% potassium and it was found, that by...
Canada Department of Energy, Mines and Resources, 1960
Five uranium solution samples obtained from leach products of the Port Radium and Port Hope plants of Eldorado Mining and Refining Limited were investigated on...
Canada Department of Energy, Mines and Resources, 1963
Two conductimetric probe systems of the immersion type were tested under normal plant conditions in the concentrator of Noranda Mines Limited. Comparison with...
Canada Department of Energy, Mines and Resources, 1963
Preliminary tests on the possible use of a conductimetric probe to control caustic soda content in 30-35% cyanide solutions indicate that adequate sensitivity...
Canada Department of Energy, Mines and Resources, 1963
Conductimetric tests have been done in the flotation and cyanidation circuit of the McIntyre mill, using the Mines Branch and Foxboro conductivity probes, to...
Canada Department of Mines and Technical Surveys, 1963
A semi-automatic device has been constructed that can be used to check the solution strength of cyanide solutions. It consists of a wheel on which a gold-foil...
Canada Department of Energy, Mines and Resources, 1962
A sample of Noranda leach pulp was tested in the pH range from 11.5 to 12.0 to establish the possibility of using the conductometric probe to control the...
Canada Department of Mines and Technical Surveys, 1961
Fluorescence under ultraviolet illumination has been in anion and cation exchange resins when in the unloaded observed state. This fluorescence decreases...
Rapport
Texte intégral en ligne
Filtrer vos résultats
Opération réussie
L’élément a été sauvegardé.
Opération réussie
Cet élément a été retiré.
Erreur
Vous avez dépassé le nombre maximal de 100 résultats sauvegardés.
Erreur
Impossible de sauvegarder l’élément. Veuillez réessayer. Si le problème persiste, il pourrait y avoir un problème avec l’élément.
Erreur
Impossible de supprimer l’article demandé. Veuillez réessayer plus tard.